Field Change Order: 2024 Date of Issue : Applicable to : Master 128 Reason for Issue: The metal plate of the new membrane keyboard is too thick to allow the fitting of the spire clip used to connect the metalwork of the keyboard and PSU together. The assembly change detailed below must be implemented when a membrane keyboard is fitted. It may also be used for the current (mechanical) keyboards. Types Affected: All product prior to introduction of membrane keyboard 0143,700 Description of Change: The spire clip, which previously fitted over the tags on both the keyboard and PSU metalwork, should now only be fitted to the PSU tag and the keyboard tab then placed on top. The securing screw is then passed through both the tags and tightened into the spire clip. Note: It is recommended that a washer (M3 internal-tooth, Acorn Part Number 0882,972) is fitted directly under the head of the securing screw. Claim Procedure: Rework Doc. Reference: 2024 FCO Credit Rate: N/A (Spec change info only) Special Instructions: